MD Series low frequency on-line UPS
Power range: 2KVA-10KVA Work mode: double conversion topology on-line Application area: workstation, Network Server, computer workroom etc.
Mono-phase input/Mono-phase output Low frequency design On-line double convention technology Central control panel Remote control management DC start Hot parallel system Perfect protection
|
Products Specification
|
Power range: 2KVA-10KVA Work mode: double conversion topology on-line Application area: workstation, Network Server, computer workroom etc.
Mono-phase input/Mono-phase output Low frequency design On-line double convention technology Central control panel Remote control management DC start Hot parallel system Perfect protection
Nice interface design, LCD/LED display the UPS operating status Built in control board design, have on need of any adjustment, easy to maintenance Overload protection: When overload, setting to auto-transfer, Overload detection and reset, if overload vanish, auto-transfer to UPS Soft start-up protection: When turn-on ups or after turn-off discharge restoration power supply for ups, avoid transient varying output Double reserve power supply system, operation reliability, to ensure power supply or precision equipments RS232 communication interface, provide intelligent supervisory software to ups The card insertion add-on SNMP(option), support remote supervisory for network |
|
Model |
B2k B3k B3.75k B5k/6k B10k |
|
Nominal capacity(PF=0.8) |
2KVA 3KVA 3.75KVA 5/6KVA 10KVA |
|
Input |
Voltage Frequency |
110VAC±20% / 220VAC +25%/-25% 60 Hz±5% / 50 Hz±5% |
|
Output |
Voltage Frequency Transient response Wave form Power factor Crest factor |
110VAC ±1% / 220VAC ±1% 60Hz ±0.5% / 50Hz ±0.5%(free running) ±4%(100% load variation)
sine wave THD<3% at 0-100% linear load 0.8-1 LAG 3:1 |
|
Battery |
Type Number VDC |
sealed lead-acid maintenance free 12V/8PCS | 12V/8 or 16PCS | 12V/16PCS 96VDC | 96 or 192 VDC | 192VDC |
|
Effective |
AC/AC |
> 85% |
|
Transfer time |
AC fault UPS fault |
Zero ≤2ms |
|
Protection |
Battery Over load
Over temperature Short circuit EMI filter |
circuit breaker 125% load, change to by-pass and auto-restart after 25s > 85℃ change to by-pass
breaker, current limited and cut-off 150-500KHz,79dB / 500KHz-30MHz,73dB |
|
Alarm |
AC fault Battery low voltage Over load UPS Fault |
alarm every 4 seconds, stop after 90 seconds alarm every 1 second until cut-off and battery LED flash every 2 seconds continue voice continue voice |
|
Display |
LED LCD
|
mains input/by pass/inverter/battery/over load/fault input, output or battery voltage/frequency/load rate/UPS condition/temperature |
|
Interface |
RS232 |
mains/inverter voltage, battery capacity, load capacity, mains frequency, temperature, time-shutdown etc.(DOS, Windows, Windows-NT, Novell Netware, UNIX) |
|
Other data |
WxDxH Weight Weight WxDxH Output Temperature Humiity Noise |
230x578x575mm | 480x340x845mm 56kg 54kg 54kg 62kg 125kg 85kg 83kg 82kg 111kg 230x579x751 mm socket | connection bus 0-40℃ 20-90% without condensation < 58dB at 1 meter | |
|